Features
  • 30 amps, 500Vac max.
  • DIN rail or panel mounting 
  • Three phase (three leg) control 
  • Zero switching 
  • Finger safe
  • LED status indicator 
RS3DA Derating graph

TECHNICAL SPECIFICATIONS

 
Dimensions (mm): 87H x 90W x 100D 
Load type: Resistive
Inputs RS3DA:
DC Logic (LDC): ON >4V/10mA, 28V/18mA max. 
OFF <1V)
DC Logic (HDC): ON >20V/11mA, 30V/21mA max.
OFF <15V
Inputs RS3DA:
AC Logic (HAC): ON >100V/10mA, 280V/33mA max.,
input impedance 0.9kž
OFF <20V
Firing mode: Logic, ON/OFF
Operating temperature: 0° to 40°C without derating