EUROTHERM QUALITY
& PERFORMANCE FOR THE BUDGET CONSCIENCE.
|
| Ideal for
plastic extruders, ovens, chillers, sterilisers, trace heating, packaging
machines |
|
|
SAFETY
MESSAGING
MESSAGE ALERTS ACTIVATED
BY ANY PARAMETER
The 3208 includes all
the features you have come to expect from Eurotherm controllers (advanced
PID control, Ramp/Dwell Timer, simple to use software & menus etc),
PLUS 15 scrolling configurable alarm, warning and/or information messages
which can be activated by any parameter.
UNIVERSAL METER
FAST VISUAL PROCESS INDICATION
The 3208 display includes a 7 segment universal meter, for simple visual indication of process status. The meter can be used to display all standard parameters, such as heat, cool or total power output, process input, signal error, CT Load amps or setpoint. The meter can also be switched off if required. The meter is also useful for semi-skilled operators or for use in applications where operator process knowledge is limited.
|
Safety Messaging tell
operators what is really happening, improving safety and process feedback.
The operator is alerted to alarm priority & exact cause. The message
can even carry instructions on how to respond. Thus
not wasting time waiting for a maintenance officer to advise that the problem
is non-critical, saving time and increasing productivity! |
|
The new 3208 1/8th
DIN controller provides a new level of user convenience. The scrolling
safety messages deliver plain language messages to let operators
and engineers alike know exactly what is happening to the process.
In addition, the 3208 also incorporates
a 7 segment universal meter for simple visual
indication of various process variables, such as error, or ac load current.
The Quick
Start Wizard makes configuration simpler than ever. At initial
power up the configuration is displayed on the lower display with clear
descriptive text providing scrolling help for each setting.
Universal inputs
enable the simple selection of any standard thermocouple, 2 or 3 wire Resistance
Thermometer or process input. A custom linearisation can be installed using
the simple PC tool, iTools.
The Load
Current Transformer Input, CT input, provides the ideal method
to monitor load current and provide immediate indication of load conditions.
Partial load failure, heater open circuit or thyristor short circuit can
each be indicated by clear scrolling operator messages and relay output.
|
The operator interface
is fully configurable enabling any parameter to be promoted for immediate
operator access on level 1 or password protected level 2. This provides
for the simplest solutions right through to sophisticated applications.
The new three
color LCD display provides clear indication of process variables.
The upper display shows the process measured value while the lower display
can be set to display a range of parameters including, setpoint, time remaining
and current.
The communications
option provides full system integration through the industry
standard modbus protocol.
Three
outputs can be configured to provide any combination
of heating, cooling and alarm. The Logic output can also be used as a Digital
Input.
Quick Code
Configuration
On initial
start-up, enter your required configuration from the table provided (refer
to the 3200 Series manual for details - HA028582
Iss 1) and your 3208 is configured, ready to
control. No messy manuals or instructions.
|
Horizontal Controller style also
available
|
TERMINATION
CONFIGURATION
RAMP
/ DWELL TIMER
Included as
standard is a multimode ramp/dwell programmer for basic setpoint batching
control and more specialised timing functions. Digital outputs are also
provided for program running and end of timer.

SETPOINT
PROGRAMMER / PROFILING
The
3208 Programmer version is a controller which also contains a four segment
setpoint programmer where each segment consists of a controlled rate ramp
to a target setpoint followed by a dwell at that setpoint. This provides
a low cost solution for applications where basic setpoint profilling is
required. The end of program can be set to dwell, control to setpoint 2
or turn off. Reset, Run and End digital
outputs can also be softwared to relay
outputs for alarming and other control requirments.

ZONE
CONTROL MASTER / BASIC CASCADE CONTROL
The
master communications feature allows the 3208 to become a master
setpoint programmer, sending its setpoint
to slave devices for zone control applications. Up to 32 slaves can be
attached. The same system allows the 3208 to be used as a basic low
cost CASCADE controller for applications
where long process times produce poor control in basic control applications.
HOT
RUNNER CONTROLLER
HOT
RUNNER Controllers are used on injection
moulding machines to stop the plastic
freezing as it runs into long narrow channels in the mould. These channels
are kept warm by embedding cartridge heaters into the mould. The cartridges
are hydroscopic (absorb water) and need to be slowly dried out to overcome
earth leakage, shorted turns and overheating. The hot runner (soft start)
controller
delivers a reduced power output until a set temperature or time is reached.
The controller then reverts to normal PID control. Phase
angle thyristors are often used to control the heaters. The
3208 DC provides a very economical solution.
CONFIGURATION
WIZARD
For simplified
configuration of messaging and all other module parameters, a free
configuration Wizard is available.
This simple Windows based Wizard uses drop-down selections to guide you
through every parameter quickly and easily, with online help making it
even easier to get the most out of your controller.
Optional configuration
clip required for controllers not fitted with communications. |
Specifications
| Dimensions: |
48W
x 96H x 90D mm |
| Text
messages: |
15
x 30 character messages |
| Control
modes: |
PID
or On/Off, heat/cool, heat only, cool only |
| Supply
voltages: |
85-264Vac,
24Vac/dc (6 watts max.) |
| Operating
ambient: |
0
to 50 deg C
5% to 85% RH, non condensing |
| Inputs: |
Thermocouples
Pt100 3 wire
0-50mV, 4-20mA, 0-20mA
Custom linearisation |
| Current
transformer input: |
50mA
ac into 10R |
| Communications: |
Modbus,
RS232, RS485 2 wire |
| Output
ratings: |
Relay:
2A, 264Vac resistive
Logic out: 12Vdc
DC Control or Retransmission:
0-20mA, 4-20mA (500 ohm max) Non isolated
Digital in: contact closure
or logic |
| Panel
sealing: |
IP65,
NEMA 4X, plug-in from front panel |
Ordering
Code and Quotation Request
3208
ORDERING CODE 32h8 ORDERING CODE |
|